RTI uses cookies to offer you the best experience online. By clicking “accept” on this website, you opt in and you agree to the use of cookies. If you would like to know more about how RTI uses cookies and how to manage them please view our Privacy Policy here. You can “opt out” or change your mind by visiting: http://optout.aboutads.info/. Click “accept” to agree.
Multicenter evaluation of use of dried blood and plasma spot speciments in quantitative assays for human immunodeficiency virus RNA
Measurement, precisions, and RNA stability
Brambilla, D., Jennings, C., Aldrovandi, G., Bremer, J., Comeau, A. M., Cassol, S. A., Dickover, R., Jackson, J. B., Pitt, J., Sullivan, J., Butcher, A., Grosso, L., Reichelderfer, P., & Fiscus, S. (2003). Multicenter evaluation of use of dried blood and plasma spot speciments in quantitative assays for human immunodeficiency virus RNA: Measurement, precisions, and RNA stability. Journal of Clinical Microbiology, 41(5), 1888-1893. https://doi.org/10.1128/JCM.41.5.1888-1893.2003
Eleven laboratories evaluated the use of dried blood and plasma spots for quantitation of human immunodeficiency virus (HIV) RNA by two commercially available RNA assays, the Roche Amplicor HIV-1 Monitor and the bioMerieux NucliSens HIV-1 QT assays. The recovery of HIV RNA was linear over a dynamic range extending from 4,000 to 500,000 HIV type 1 RNA copies/ml. The Monitor assay appeared to have a broader dynamic range and seemed more sensitive at lower concentrations. However, the NucliSens assay gave more consistent results and could be performed without modification of the kit. HIV RNA was stable in dried whole blood or plasma stored at room temperature or at -70 degrees C for up to 1 year. Dried blood and dried plasma spots can be used as an easy and inexpensive means for the collection and storage of specimens under field conditions for the diagnosis of HIV infection and the monitoring of antiretroviral therapy