RTI uses cookies to offer you the best experience online. By clicking “accept” on this website, you opt in and you agree to the use of cookies. If you would like to know more about how RTI uses cookies and how to manage them please view our Privacy Policy here. You can “opt out” or change your mind by visiting: http://optout.aboutads.info/. Click “accept” to agree.
Development and implementation of a proficiency testing program for Luminex bead-based cytokine assays
Lynch, H. E., Sanchez, A. M., D'Souza, M. P., Rountree, W., Denny, T. N., Kalos, M., & Sempowski, G. D. (2014). Development and implementation of a proficiency testing program for Luminex bead-based cytokine assays. Journal of Immunological Methods, 409, 62-71. https://doi.org/10.1016/j.jim.2014.04.011
Luminex bead array assays are widely used for rapid biomarker quantification due to the ability to measure up to 100 unique analytes in a single well of a 96-well plate. There has been, however, no comprehensive analysis of variables impacting assay performance, nor development of a standardized proficiency testing program for laboratories performing these assays. To meet this need, the NIH/NIAID and the Cancer Immunotherapy Consortium of the Cancer Research Institute collaborated to develop and implement a Luminex assay proficiency testing program as part of the NIH/NIAID-sponsored External Quality Assurance Program Oversight Laboratory (EQAPOL) at Duke University. The program currently monitors 25 domestic and international sites with two external proficiency panels per year. Each panel includes a de-identified commercial Luminex assay kit with standards to quantify human IFNγ, TNFα, IL-6, IL-10 and IL-2, and a series of recombinant cytokine-spiked human serum samples. All aspects of panel development, testing and shipping are performed under GCLP by EQAPOL support teams. Following development testing, a comprehensive site proficiency scoring system comprised of timeliness, protocol adherence, accuracy and precision was implemented. The overall mean proficiency score across three rounds of testing has remained stable (EP3: 76%, EP4: 75%, EP5: 77%); however, a more detailed analysis of site reported results indicates a significant improvement of intra- (within) and inter- (between) site variation, suggesting that training and remediation for poor performing sites may be having a positive impact on proficiency. Through continued proficiency testing, identification of variables affecting Luminex assay outcomes will strengthen efforts to bring standardization to the field.