RTI uses cookies to offer you the best experience online. By clicking “accept” on this website, you opt in and you agree to the use of cookies. If you would like to know more about how RTI uses cookies and how to manage them please view our Privacy Policy here. You can “opt out” or change your mind by visiting: http://optout.aboutads.info/. Click “accept” to agree.
Evaluating PM2.5 element concentration measurements for a nationwide monitoring network
Rosales, C. M. F., Weber, F., Dombek, T. L., Levine, K., McWilliams, A., Spada, N. J., & Hyslop, N. P. (2023). Evaluating PM2.5 element concentration measurements for a nationwide monitoring network. Journal of the Air and Waste Management Association, (10). https://doi.org/10.1080/10962247.2023.2247376
Particulate matter (PM) concentrations have decreased dramatically over the past 20 years, thus lower method detection limits (MDL) are required for these measurements. Energy-dispersive X-ray fluorescence (XRF) spectroscopy is used to quantify multiple elements simultaneously in the United States Environmental Protection Agency (US EPA) Chemical Speciation Network (CSN). Inductively-coupled plasma mass spectrometry (ICP-MS) is an alternative analysis with lower MDL for elements. Here, we present a side-by-side comparison of XRF and ICP-MS for elements in PM2.5 samples collected via the US EPA's CSN. For ICP-MS, a simple extraction and ICP-MS analysis technique was applied to a wide variety of samples to minimize effort and cost and serve as a feasibility test for a large monitoring network. Filter samples (N = 549) from various urban locations across the US were analyzed first analyzed via XRF at UC Davis and then ICP-MS at RTI International. Both methods measured 29 of the same elements out of the 33 usually reported to CSN. Of these 29, 14 elements (Na, Mg, Al, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Pb) were found to be frequently detected (i.e. had more than 10% of values above both XRF and ICP-MS MDL). ICP-MS was found to have lower MDL for 26 out of 29 elements, namely Na, Mg, Al, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, As, Se, Rb, Sr, Zr, Ag, Cd, In, Sn, Sb, Cs, Ba, Ce, Pb; conversely, XRF had lower MDL for 3 elements, namely, P, K, Zn. Intra-method quality checks using (1) inter-elemental inspection of scatter plots using a priori knowledge of element sources and (2) scatter plots of routine versus collocated measurements reveal that ICP-MS exhibits better measurement precision. Lower detection limits for element measurements in nationwide PM monitoring networks would benefit human-health and source apportionment research.